Torch installation, Nc c no – Hypertherm HD4070 Rev.8 User Manual

Page 77

Advertising
background image

1-TORCH INSTALLATION

3

HD4070

Instruction Manual

3A-15

X-Y Lifter Assembly Optional Torch Breakaway Kit Mounting Details

Fiberglass bracket

Breakaway

X-Y Lifter

Hex screws (4)

Hex screws (2)

Connect to

emergency

stop circuit

Tubing

6 screws

Collar

Collar

Block

Brown

1-5/16 inch

(33.34 mm)

Filter/Regulator

Breakaway

Breakaway

pressure switch,

Normally Open

Moisture drain

Inlet port
1/4 inch NPTF
100 psi (6.9 bar)

Customer supplied
hex screws (2)
8-32 X 1-1/2 inch
or 4 mm x 40 mm

Blue

(Not Connected)

Black

Tubing connector

Spacer and 4 hex screws not
used if breakaway is installed.

10

1

1

2

3

3

6

4

5

5

7

8

10

8

3

2

NC

C

NO

Pressure gauge