SPECIFICATIONS

3

HD4070

Instruction Manual

2-5

Specifications

System gas requirements

Gas Quality and Pressure Requirements

Quality

Pressure + 5%

Flow Rate

O

2

Oxygen

99.5% pure (liquid gas recommended)

120 psi

133 scfh (3780 l/h)

Clean, dry, oil-free

8.3 bar / 827 kPa

N

2

Nitrogen

99.99% pure (liquid gas recommended)

120 psi

142 scfh 4020 l/h

Clean, dry, oil-free

8.3 bar / 827 kPa

Air

Clean, dry, oil-free

120 psi

140 scfh 3960 l/h

8.3 bar / 827 kPa

CH

4

Methane

93% pure

120 psi

188 scfh 5340 l/h

8.3 bar / 827 kPa

H5 Argon-Hydrogen

99.995% pure (liquid gas recommended)

120 psi

122 scfh 3420 l/h

(H5=5% Hydrogen, 95% Argon)

8.3 bar / 827 kPa

H35 Argon-Hydrogen

99.995% pure (liquid gas recommended)

120 psi

146 scfh 4140 l/h

(H35=35% Hydrogen, 65% Argon)

8.3 bar / 827 kPa

*CO

2

Carbon-Dioxide

99.5% pure

120 psi

113 scfh 3180 l/h

8.3 bar / 827 kPa

Mild Steel

Stainless Steel

Aluminum

Gas Types

Plasma

Shield

Plasma

Shield

Plasma

Shield

Marking

N

2

N

2

H5

N

2

H5

N

2

Cutting 30 A

O

2

O

2

& N

2

Air

Air

Air

Air

Cutting 70 A

O

2

O

2

& N

2

H35 & N

2

N

2

Air

CH

4

& Air

Cutting 100 A to 200 A

O

2

O

2

& N

2

H35 & N

2

N

2

H35 & N

2

N

2

*CO

2

is not currently used on the HD4070 and there is no need to install the gas line.