Mount the Ignition Console Assembly

Mount the ignition console on the gantry (bridge). Allow room to remove the top for servicing. Maximum
length of the leads between the ignition console and the torch is 15 feet (4.5 m).

Mount the ignition console horizontally, or in the vertical position as shown below.

2-Torch Systems: 2 ignition consoles are required for a 2-torch system.

3

Vertical Mounting

Horizontal Mounting

4070.19

0

0

1.25" (32 mm)

11.0"
(279 mm)

9.75"
(248 mm)

0.28"

(7 mm)

1.25"
(32 mm)

10.63" (270 mm)

4070.21