INSTALLATION
0
HD4070
Instruction Manual
3-5
Placement of System Components
• Place all system components in position prior to making electrical, gas and interface connections. Use the
diagram on the following page for component placement guidelines.
• Ground all system components to earth. See Grounding Requirements in this section for details.
• To prevent leaks in the system, tighten all gas and water connections as shown below:
Torque Specifications
Gas or Water
Hose Size
lbf-in
lbf-ft
kgf-cm
Up to 3/8" (10 mm)
75-85
6.25-7
8.6-9.8
1/2" (12 mm)
360-480
30-40
41.5-55
2WRENCHES