Cable entry – LSC Lighting Redback Wallmount Operators Manual User Manual

Page 12

Advertising
background image

Installation

Redback Wallmount Dimmer

Operator Manual V1.3

Page 8

2.6.1.3 24 channel Redbacks

24 channel Redback can be powered from:

Three phase supply of nominal or 220-240VACv at 50 - 60Hz of up to 80 Amps per
phase. See Neutral rating note above.

Single phase supply of nominal or 220-240VAC* at 50 - 60Hz of up to 120 Amps.
The input power connectors are limited to 120 Amps so it is imperative that the
single phase supply is current is also limited to 120 Amps.

*100-120VAC versions are available by special order from the factory.

Safety Note: Conversion between three phase and single phase operation should only be
undertaken by a suitably trained and qualified electrical technician.

2.6.2 Cable Entry

Redback Wallmount dimmers are fitted with removable cable duct plates on the top right
and bottom right of the unit.


The bottom plate is provided with a cable knock-out entry. To remove the knock-out insert
a flat blade screwdriver in the slot provided and twist out the metal disk and fit a M32 cable
gland.
























Duct entry plate
with cable

knock out.

No user

access from

this plate