Redback Wallmount Dimmer

Wall Plates

Operator Manual V1.3

Page 37


Therefore, in the example above, pressing the button for control line 3 will fade up memory
3. Pressing the button for 6 will decrease all of the channel levels in memory 3 by 5%. Press
it again for another 5% decrease. Presses of the button for 5 will fade memory 3 back up.
Note: With this configuration, memories 5 and 6 are no longer available.

5.3.6 Link

Adjacent “toggle” buttons within a group can be linked (or un-linked) by selecting them and
clicking [Link].
A Linked button ACTIVATES its memory and DEACTIVATES all other memories to which it
has been linked.
For example, buttons 1 and 2 have been linked.


Pressing control line 1 will fade up memory 1.
Pressing control line 2 will fade up memory 2 AND fade down memory 1.
Pressing control line 1 again will fade up memory 1 AND fade down memory 2.
In the following example, a 6 button wall plate controls 6 memories and only the latest
memory to be pressed will be active.