5.3.4 Wall Plates Setup Menu
The default configuration of the “Wall Plates Setup” menu is for buttons 1 to 6 to “Toggle”
memories 1 to 6 ON or OFF. Therefore, press a button to fade up its memory. Press it again
to fade it down.
For example, pressing button 1 on a wall plate (with default button jumpers) would fade up
memory 1. Pressing it again would fade it down.
Selecting [Config] [System] [Wall plate Setup] reveals the “Wall Plates Setup” menu:
This menu allows you to group and link buttons and then change their functions as
described below.
5.3.5 Group
Adjacent buttons can be grouped (or un-grouped) by selecting them and clicking [Group].
For example, a 2 button group and a 4 button group could be configured as follows:
Buttons in a group can be configured as either “Toggle”, “ Inc” or “ Dec”.
“ Inc” or “ Dec” buttons are usually configured in groups that contain 3 or more buttons.
One or more buttons in the group are set as “Toggle” and they control their relevant
memory(s). The “ Inc” or “ Dec” buttons in the group then allow you to control (raise or
lower) all the active (faded up) memories in the same group.
Each press of a Dec button on a wall plate will decrease the intensities of the
ACTIVE memory(s) in the group by 5%.
Each press of a Inc button on a wall plate will increase the intensities of the
ACTIVE memory(s) in the group by 5%.
To configure a button as “ Inc” or “ Dec”, there must be a “Toggle” button in the same
group. Select a button in the group then press either [ Inc] or [ Dec].
For example, buttons 5 and 6 have been configured as Inc and Dec:
Control line
number
Memory