707023-003

8. ASCII Port Options

ASCII Port Options

LINCS C8.2 Central Control

Port

Port

Baud

Line

Flow

Stop

Data Bits

Number

Type

Rate

Type

Control

Bits

& Parity

ADAA.000

None

19200

Non-Switched

XON/XOFF

1.5

7, Even, NC

ADAA.001

Host

9600

Direct

XON/XOFF

1

8, None

ADAA.002

Host

9600

Direct

XON/XOFF

1

8, None

ADAA.003

Display

9600

Direct

XON/XOFF

1

8, None

ADAA.004

Display

9600

Direct

XON/XOFF

1

8, None

ADAA.005

Display

9600

Direct

XON/XOFF

1

8, None

ADAA.006

Printer

9600

Direct

XON/XOFF

1

8, None

ADAA.007

Printer

9600

Direct

XON/XOFF

1

8, None

PF: 1-Menu

7-Back

8-Forw

9-Default

10-Done

An ASCII Port Options panel appears for each set of eight ASCII ports. It enables you to
configure the port type (host, display, or printer) and some other communications parameters
for the port.

Port Number

This is the board and connector, referred to as ASCII port number. In this example, ADA
board A (first one).

Port Type

Choose the type of ASCII host or device attached to each port. Options are:

• Host

• Display

• Printer

• None

Baud Rate

Check one of the following baud rates for each port:

• 300

• 600

• 1200

• 2400

• 4800

• 9600 (default)

• 19200

• AUTO (for display stations only)

The auto baud/auto parity (AUTO) option allows LINCS to recognize the ASCII display
station’s baud rate and parity, using key input from the user.