Technical specifications

Table 53 FIP-210 specifications

Item

Specification

Flash 4

MB

Memory type and size

•

Default—Two 1-GB DDR2 SDRAMs

•

Maximum—Two 2-GB DDR2 SDRAMs

NVRAM 128

KB

Combo interfaces

2

2 copper ports (automatic
MDI/MDIX)

10 Mbps, half/full-duplex

100 Mbps, half/full-duplex

1000 Mbps, full-duplex

2 fiber ports

1000 Mbps, full-duplex

HIM

2 HIMs supported

MIM

2 MIMs supported

Dimensions (H × W × D)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

Hardware encryption

Supported

Power consumption

125 W

Hot swapping

Supported

NOTE:
•

For a combo interface, the default operating port is the copper port.

•

For a combo interface, you can use either the copper port or the fiber port. To switch between the copper
and fiber ports, use the combo enable { copper | fiber } command in interface view. For more

information about the combo enable { copper | fiber } command, see

H3C SR6600 Routers Interface

Command Reference.

•

Use transceiver modules for the fiber ports provided by H3C only. The router might be incompatible with
transceiver modules from other manufacturers. The system generates an alarm when a transceiver

module from another manufacturer is installed.

FIP-210 combo interface specifications

Specification of combo interfaces on the FIP-210 and the FIP-110 are the same. For more information,

see

Table 48

and

Table 49

.

Transceiver modules for the FIP-210 and for the FIP-110 fiber ports are the same. For more information,
see

Table 50

.

Maximum interface modules provided by FIP-210 in full configuration

Table 54 Maximum interface modules provided by FIP-210 in full configuration

Interface

module

One RPE-X1

Two RPE-X1s

One RSE-X1

Two RSE-X1s

SR6604 SR6608 SR6604 SR6608 SR6604 SR6608 SR6604 SR6608

FIP-210

2 4 2 4 2 4 1 3

Advertising