TNC 425/TNC 415 B/TNC 407
9-30
9
3D Touch Probe Systems
Before cycle 16: MEANDER, the program must have a range defined in cycle 5: RANGE or cycle 15: RANGE
(TABLE).
.
.
.
e.g.
1
0 0
0
ENT
Resulting NC blocks:
TCH PROBE
16.0 MEANDER
TCH PROBE
16.1 DIRECTN: X
ANGLE
TCH PROBE
16.2 F1000 MIN.L.SPAC: 0.2
L.SPAC: 0.5 PP.INT: 0.5 TOL: 0.1
e.g.
0
ENT
2
e.g.
0
ENT
5
e.g.
0
ENT
5
e.g.
0
ENT
1
Digitizing with a Measuring Touch Probe
TOLERANCE ?
Enter the diameter of the tubular tolerance zone, for example
0.1 mm.
MAX. PROBE POINT INTERVAL ?
Enter the maximum probe point interval, for example 0.5 mm.
LINE SPACING ?
Enter the maximum spacing between lines, for example 0.5 mm.
FEED RATE ?
F=
Enter the digitizing speed, for example 1000 mm/min.
MIN. LINE SPACING ?