HEIDENHAIN TNC 407 (280 580) User Manual User Manual
Page 309

TNC 425/TNC 415 B/TNC 407
9-42
9
3D Touch Probe Systems
e.g.
TOUCH
PROBE
GOTO
5
ENT
Z
ENT
To program TCH PROBE 5.0:
TCH PROBE: 0 REF. PLANE
Select digitizing cycle 5: RANGE.
TCH PROBE: 5 RANGE
Confirm your selection.
PGM NAME DIGITIZING DATA?
Enter the name of the file in which the digitizing data should be stored.
TCH PROBE AXIS?
Enter the touch probe axis.
e.g.
1 0
e.g.
1 0
e.g.
0
2
e.g.
1 0
0
ENT
ENT
ENT
ENT
0
e.g.
0
0
ENT
ENT
ENT
Digitizing with the TS 120 Touch Probe
MIN. POINT RANGE?
Enter in sequence the X, Y and Z coordinates of the range MIN point.
MAX. POINT RANGE?
Enter in sequence the X, Y and Z coordinates of the range MAX
point.
CLEARANCE HEIGHT?
Enter the clearance height for the touch probe.
Resulting NC blocks:
TCH PROBE
5.0
RANGE
TCH PROBE
5.1
PGM NAME: DATA
TCH PROBE
5.2
Z
X+0 Y+0 Z+0
TCH PROBE
5.3
X+10 Y+10 Z+20
TCH PROBE
5.4
HEIGHT: + 100