HEIDENHAIN TNC 407 (280 580) User Manual User Manual
Page 317

TNC 425/TNC 415 B/TNC 407
9-50
9
3D Touch Probe Systems
1
e.g.
ENT
2
X
e.g.
ENT
TOUCH
PROBE
GOTO
8
ENT
ENT
0
5
e.g.
ENT
0
e.g.
ENT
5
0
e.g.
ENT
2
Digitizing with the TS 120 Touch Probe
LINE SPACING?
Enter the desired spacing between lines, for example 0.2 mm.
MAX. PROBE POINT INTERVAL?
Enter the maximum probe point interval, for example 0.5 mm.
Resulting NC blocks:
TCH PROBE 8.0
LINE
TCH PROBE 8.1
DIRECTN: X–
TCH PROBE 8.2
TRAVEL: 0.5 L.SPAC: 0.2
PP.INT: 0.5
Before cycle 8: LINE, the program must have a range defined in digitizing cycle 5: RANGE.
LIMIT IN NORMAL LINES DIRECTION?
Enter the distance of travel by which the probe lifts off the surface
during scanning, for example 0.5 mm.
HEIGHT FOR FEED RATE DECREASE ?
Enter the probe axis coordinate at which the probing feed rate is
reduced from rapid traverse to the probing feed rate, e.g. +12 mm.
To program TCH PROBE 8.0:
TCH PROBE: 0 REF. PLANE
Select the scanning cycle 8 LINE.
TCH PROBE: 8 LINE
Confirm your selection.
LINE DIRECTION ?
Enter the line direction, for example –X.