HEIDENHAIN TNC 407 (280 580) User Manual User Manual
Page 348

12-4
12
Tables and Overviews
TNC 425/TNC 415 B/TNC 407
Type of touch probe
MP6200
Triggering touch probe:
0
Measuring touch probe:
1
Type of transmission
MP6010
Cable transmission:
0
Infrared transmission:
1
Probe feed rate for TS 120/TS 511
MP6120
80 to 3000 [mm/min]
Maximum traverse to first probe point
MP6130
0 to 99 999.9999 [mm]
Safety clearance to probe point during automatic measurement
MP6140
0 to 99 999.9999 [mm]
Rapid traverse for probing with TS 120/TS 511
MP6150
1 to 300 000 [mm/min]
Measure center misalignment of stylus for calibration of TT 120/TS 511
MP6160
No 180° rotation of 3D touch probe during calibration:
0
M function for 180° rotation of touch probe during calibration:
1 to 88
Lubrication of touch probe axis during digitizing with TS 120
MP6220
Traverse in the touch probe axis at end of line:
0 to 99 999.9999 [mm]
Lubrication of touch probe axis during digitizing with TS 120
MP6221
Lubricate after:
0 to 65 535 [sec]
3D touch probes and digitizing