F7u parameters 4-18 – Yaskawa F7 Modbus User Manual

Page 57

Advertising
background image

F7U Parameters 4-18

Table 4.11 – H Parameters

Mode

Name

Addr

Digital Operator

Text

Data

Parameter Range or

Data Description

Inc

Default

Run

V/f

V/f

wPG

OLV

FV

Dep

0 0-10

VDC

H3-04

0413h

Term A3 Signal

1

-10 +10 VDC

1

0

A A A A

0 Frequency

Bias

1 Frequency

Gain

2 Aux

Reference

3 Voltage

Bias

4 Acc/Dec

Change

5

DC Brake Current

6 Overtorque

Level

7

Stall Prev Level

8 Ref

Lower

Limit

9 Jump

Frequency

10 PI

Feedback

11

PI Set Point

12

Frequency Bias 2

13 MotorTemperature
14

Fwd Torque Limit

15

Rev Torque Limit

16

Regen Torq Limit

17 Torque

Reference

18 Torque

Comp

19 Torque

Limit

20 PI

Differential

21 Not

Used

22

CASE AI 1

H3-05

0414h

Terminal A3 Sel

23

CASE AI 2

1

02h

A A A A

H3-06

0415h

Terminal A3 Gain

0.0 ~ 1000.0 %

0.1 %

100.00 %

R

A

A

A

A

H3-07

0416h

Terminal A3 Bias

-100.0 ~ 100.0 %

0.1 %

0.00 %

R

A

A

A

A

0 0-10

VDC

1

-10 +10 VDC

H3-08

0417h

Term A2 Signal

2 4-20

mA

1

2

A A A A

0 Frequency

Bias

1 Frequency

Gain

2 Aux

Reference

3 Voltage

Bias

4 Acc/Dec

Change

5

DC Brake Current

6 Overtorque

Level

7

Stall Prev Level

8 Ref

Lower

Limit

9 Jump

Frequency

10 PI

Feedback

11

PI Set Point

12

Frequency Bias 2

13 MotorTemperature
14

Fwd Torque Limit

15

Rev Torque Limit

16

Regen Torq Limit

17 Torque

Reference

18 Torque

Comp

19 Torque

Limit

20 PI

Differential

21 Not

Used

22

CASE AI 1

H3-09

0418h

Terminal A2 Sel

23

CASE AI 2

1

0h

A A A A

H3-10

0419h

Terminal A2 Gain

0.0 ~ 1000.0 %

0.1 %

100.00 %

R

A

A

A

A

H3-11

041Ah

Terminal A2 Bias

-100.0 ~ 100.0 %

0.1 %

0.00 %

R

A

A

A

A

H3-12

041Bh

Filter Avg Time

0.0 ~ 2.0 Sec

0.01 Sec

0.03 Sec

A

A

A

A

0 Std

Fan

Cooled

1 Std

BlowerCooled

2 Vector

Motor

3 Frequency

Ref

4 Output

Freq

5 Output

Current

6 Control

Method

7 Motor

Speed

8 Output

Voltage

9

DC Bus Voltage

10 Output

kWatts

11 Torque

Reference

12

Input Term Sts

13

Output Term Sts

14

Int Ctl Sts 1

H4-01

041Dh

Terminal FM Sel

15 Elapsed

Time

1

02h

A A A A

Advertising
This manual is related to the following products: