Table 5.1 – User Parameter Settings

Parm

Text

Default

User

Notes

d5-02

Torq Ref Filter

0 ms

d5-03

Speed Limit Sel

1

d5-04

Speed Lmt Value

0 %

d5-05

Speed Lmt Bias

10 %

d5-06

Ref Hold Time

0 ms

d6-01 Field-Weak

Lvl 80

%

d6-02 Field-Weak

Freq 0.0

Hz

d6-03 Field

Force

Sel

0

d6-06 FieldForce

Limit 400

%

E1-01

Input Voltage

200 VAC

E1-03 V/F

Selection

0fh

E1-04

Max Frequency

60.0 Hz

E1-05

Max Voltage

230.0 VAC

E1-06

Base Frequency

60.0 Hz

E1-07

Mid Frequency A

3.0 Hz

E1-08

Mid Voltage A

13.0 VAC

E1-09

Min Frequency

1.5 Hz

E1-10

Min Voltage

9.0 VAC

E1-11

Mid Frequency B

0.0 Hz

E1-12

Mid Voltage B

0.0 VAC

E1-13

Base Voltage

230.0 VAC

E2-01

Motor Rated FLA

14.0 A

E2-02

Motor Rated Slip

3.3 Hz

E2-03 No-Load

Current 4.5

A

E2-04 Number

of

Poles

4

E2-05

Term Resistance

0.771 Ohm

E2-06 Leak

Inductance 19.60

%

E2-07 Saturation

Comp1

0

E2-08 Saturation

Comp2

0

E2-09 Mechanical

Loss 0.00

%

E2-10

Tcomp Iron Loss

0 W

E2-11

Mtr Rated Power

0.4 kW

E2-12 Saturation

Comp3

1.3

E3-01 Control

Method

2

E3-02

Max Frequency

60.0 Hz

E3-03

Max Voltage

230.0 VAC

E3-04

Base Frequency

60.0 Hz

E3-05

Mid Frequency

3.0 Hz

E3-06

Mid Voltage

10.0 VAC

E3-07

Min Frequency

0.5 Hz