N Parameters -

Table 4.13 – n Parameters –

Mode

Name

Addr

Digital Operator

Text

Data

Parameter Range or

Data Description

Inc

Default

Run

V/f

V/f

wPG

OLV

FV

Dep

0 Disabled

n1-01

0580h

Hunt Prev Select

1 Enabled

1

1

A

A

NA

NA

n1-02

0581h

Hunt Prev Gain

0.0 ~ 2.5

0.01

1

A

A

NA

NA

n2-01

0584h

AFR Gain

0.0 ~ 10.0

0.01

1

NA

NA

A

NA

n2-02

0585h

AFR Time

0 ~ 2000 ms

1 ms

50 ms

NA

NA

A

NA

n2-03

586h

AFR Time 2

0 ~ 2000 ms

1 ms

750 ms

NA

NA

A

NA

n3-01

0588h

HSB Decel Width

1 ~ 20 %

1 %

5 %

A

A

NA

NA

n3-02

0589h

HSB Current Ref

100 ~ 200 %

1 %

150 %

A

A

NA

NA

n3-03

058Ah

HSB DwelTim@Stp

0.0 ~ 10.0 Sec

0.1 Sec

1.0 Sec

A

A

NA

NA

n3-04

058Bh

HSB OL Time

30 ~ 1200 Sec

1 Sec

40 Sec

A

A

NA

NA

O Parameters

Table 4.2 – o Parameters

Mode

Name

Addr

Digital Operator

Text

Data

Parameter Range or

Data Description

Inc

Default

Run

V/f

V/f

wPG

OLV

FV

Dep

o1-01

0500h

User Monitor Sel

4 ~ 99

1

6

R

A

A

A

A

o1-02

0501h

Power-On Monitor

1 ~ 4

1

1

R

A

A

A

A

o1-03

0502h

Display Scaling

0 ~ 39999

1

0

A

A

A

A

o1-04

0503h

Display Units

0 ~ 1

1

0

NA

NA

NA

A

o1-05

0504h

LCD Contrast

0 ~ 5

1

3

R

A

A

A

A

o2-01

0505h

Local/Remote Key

0 ~ 1

1

1

A

A

A

A

o2-02

0506h

Oper STOP Key

0 ~ 1

1

1

A

A

A

A

o2-03

0507h

User Defaults

0 ~ 2

1

0

A

A

A

A

o2-04

0508h

Inverter Model #

0h ~ FFh

1

0h

A

A

A

A

A1-03

o2-04

o2-05

0509h

Operator M.O.P.

0 ~ 1

1

0

A

A

A

A

o2-06

050Ah

Oper Detection

0 ~ 1

1

0

A

A

A

A

o2-07

050Bh

Elapsed Time Set

0 ~ 65535

1

0

A

A

A

A

o2-08

050Ch

Elapsed Time Run

0 ~ 1

1

0

A

A

A

A

o2-09

050Dh

Init Mode Sel

1 ~ 2

1

1

A

A

A

A

A1-03

o2-10

050Eh

Fan ON Time Set

0 ~ 65535

1

0

A

A

A

A

o2-12

0510h

FLT Trace Init

0 ~ 1

1

0

A

A

A

A

o2-14

0512h

kWh Monitor Init

0 ~ 1

1

0

A

A

A

A

o3-01

0515h

Copy Funtion Sel

0 ~ 3

1

0

A

A

A

A

o3-02

0516h

Read Allowable

0 ~ 1

1

0

A

A

A

A

P Parameters

Table 4.15 – P Parameters

Mode

Name

Addr

Digital Operator

Text

Data

Parameter Range or

Data Description

Inc

Default

Run

V/f

V/f

wPG

OLV

FV

Dep

P1-01

0600h

CASE Param 1

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-02

0601h

CASE Param 2

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-03

0602h

CASE Param 3

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-04

0603h

CASE Param 4

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-05

0604h

CASE Param 5

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-06

0605h

CASE Param 6

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-07

0606h

CASE Param 7

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-08

0607h

CASE Param 8

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-09

0608h

CASE Param 9

0.0 ~ 100.0

0.01

0

A

A

A

A

P1-10

0609h

CASE Param 10

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-01

060Ah

CASE Param 11

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-02

060Bh

CASE Param 12

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-03

060Ch

CASE Param 13

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-04

060Dh

CASE Param 14

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-05

060Eh

CASE Param 15

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-06

060Fh

CASE Param 16

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-07

0610h

CASE Param 17

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-08

0611h

CASE Param 18

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-09

0612h

CASE Param 19

0.0 ~ 100.0

0.01

0

A

A

A

A

P2-10

0613h

CASE Param 20

0.0 ~ 100.0

0.01

0

A

A

A

A

P3-01

0614h

CASE Param 21

0.0 ~ 100.0

0.01

0

A

A

A

A

P3-02

0615h

CASE Param 22

0.0 ~ 100.0

0.01

0

A

A

A

A