4 Operation
4.3.4 Digital Operator Displays during Testing without Motor
4-30
4.3.4 Digital Operator Displays during Testing without Motor
An asterisk (
∗) is displayed before status display to indicate the test without a motor operation is in progress.
(Example: Status of power to the servomotor is OFF)
Note: The test without a motor status is not displayed during alarm occurs (A.
).
Display
Status
∗RUN
Power is supplied to the servomotor.
∗BB
Power to the servomotor is OFF.
∗PT NT
Forward or reverse run is prohibited.
∗P-OT
Forward run is prohibited.
∗N-OT
Reverse run is prohibited.
∗HBB
In hard-wire base block (safety) state.
∗ B B
− P R M / M O N −
U n 0 0 0 =
0
0 0 0 0 0
U n 0 0 2 =
0
0 0 0 0 0
U n 0 0 8 =
0
0 0 0 0 0 0 0 0 0 0
U n 0 0 D =
0
0 0 0 0 0 0 0 0 0 0