Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual

Page 126

Advertising
background image

4 Operation

4.3.4 Digital Operator Displays during Testing without Motor

4-30

4.3.4 Digital Operator Displays during Testing without Motor

An asterisk (

∗) is displayed before status display to indicate the test without a motor operation is in progress.

(Example: Status of power to the servomotor is OFF)

Note: The test without a motor status is not displayed during alarm occurs (A.

).

Display

Status

∗RUN

Power is supplied to the servomotor.

∗BB

Power to the servomotor is OFF.

∗PT NT

Forward or reverse run is prohibited.

∗P-OT

Forward run is prohibited.

∗N-OT

Reverse run is prohibited.

∗HBB

In hard-wire base block (safety) state.

∗ B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0

Advertising