9 Troubleshooting

9.1.2 Troubleshooting of Alarms

9-14

A.830:
Absolute Encoder

Battery Error
(The absolute encoder

battery voltage is lower

than the specified value.)

The battery connection is incor-

rect.

Check the battery connection.

Reconnect the battery.

The battery voltage is lower than

the specified value 2.7 V.

Measure the battery voltage.

Replace the battery.

A fault occurred in the SERVO-

PACK.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.840:
Encoder Data Error
(Detected on the encoder

side.)

An encoder malfunctioned.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the servomotor may be

faulty. Replace the servomotor.

Malfunction of encoder because

of noise interference, etc.

Correct the wiring around the

encoder by separating the encoder

cable from the servomotor main cir-

cuit cable or by checking the

grounding and other wiring.

A.850:
Encoder Overspeed
(Detected when the con-

trol power supply was

turned ON.)
(Detected on the encoder

side.)

The servomotor speed is higher
than 200 min

-1

when the control

power supply was turned ON.

Check the motor rotating speed

(Un000) to confirm the servomotor

speed when the power is turned ON.

Reduce the servomotor speed to a
value less than 200 min

-1

, and turn

ON the control power supply.

An encoder fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the servomotor may be

faulty. Replace the servomotor.

A fault occurred in the SERVO-

PACK.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

A.860:
Encoder Overheated
(Only when an absolute

encoder is connected.)
(Detected on the encoder

side.)

The ambient operating tempera-

ture around the servomotor is too

high.

Measure the ambient operating tem-

perature around the servomotor.

The ambient operating temperature

must be 40

°C or less.

The motor load is greater than the

rated load.

Check the accumulated load ratio

(Un009) to see the load.

The motor load must be within the

specified range.

An encoder fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the servomotor may be

faulty. Replace the servomotor.

A fault occurred in the SERVO-

PACK.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

A.8A0:
External Encoder

Error

Setting the zero point position of
external absolute encoder failed
because the servomotor rotated.

Before setting the zero point posi-
tion, use the fully-closed feedback
pulse counter (Un00E) to confirm
that the servomotor is not rotating.

The servomotor must be stopped
while setting the zero point posi-
tion.

An external encoder fault
occurred.

Replace the external encoder.

A.8A1:
External Encoder

Error of Module

An external encoder fault
occurred.

Replace the external encoder.

A serial converter unit fault
occurred.

Replace the serial converter unit.

A.8A2:
External Encoder

Error of Sensor
(Incremental)

An external encoder fault
occurred.

Replace the external encoder.

A.8A3:
External Encoder

Error of Position
(Absolute)

An external absolute encoder
fault occurred.

The external absolute encoder may
be faulty. Refer to the encoder man-
ufacturer’s instruction manual for
corrective actions.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Advertising