8 Fully-closed Loop Control

8-12

8.2 SERVOPACK and Converter Startup Procedure

First check that the SERVOPACK and converter operate correctly with semi-closed loop control, then check

that they operate correctly with fully-closed loop control.

The following describes the startup procedure for the SERVOPACK in fully-closed loop control.

Procedure

Description

Operation

Parameters Requiring

Settings

Controller

1

Check operation of the whole
sequence in semi-closed loop
control and without any load.

Items to Check

• Power supply circuit wiring
• Servomotor wiring
• Encoder wiring
• Wiring of I/O signal lines from

the host controller

• Servomotor rotation direction,

speed, and number of rotations

• Operation of safety mecha-

nisms, such as the brakes and
the overtravel mechanism

Set the parameters so that the SER-
VOPACK operates correctly in

semi-closed loop control (Pn002.3
= 0) without any load and check
the following points.

• Is there an error with the SER-

VOPACK or converter?

• Does the JOG operation operate

correctly when operating the
SERVOPACK in standalone
mode?

• Do the I/O signals turn ON/OFF

correctly?

• Does the servomotor turn ON

when the Servo ON command is
turned ON from the host control-
ler?

• Does the servomotor operate

correctly when the position ref-
erence is input by the host con-
troller?

• Basic Function Select Switch

0 (Pn000)

• Application Function Select

Switch 1 (Pn001)

• External Encoder Usage

(Pn002.3)

• Electronic Gear Ratio

(Numerator) (Pn20E)

• Electronic Gear Ratio

(Denominator) (Pn210)

• Input Signal Selection

(Pn50A, Pn50B, Pn511)

• Output Signal Selection

(Pn50E, Pn50F, Pn510)

SERVOPACK or
host controller

2

Check operation of the system
connected with the machine and
servomotor in semi-closed loop
control mode.

Items to Check

• Initial responsiveness of the

system connected with the
machine

• Movement direction, distance,

and speed of the machine spec-
ified by the host controller

Connect the servomotor to the
machine.
Set the moment of inertia ratio
(Pn103) using the advanced auto-
tuning function.
Check that the machine operates in
the correct direction, distance, and
speed as directed by the host con-
troller.

• Moment of inertia ratio

(Pn103)

Host controller