9.1 Alarm Displays

9-5

9

Trou

blesh

ooting

A.E51

Command Option Module

IF Synchronization

Establishment Error

A error occurred in establishing communications between the SER-
VOPACK and the command option module.

Gr.2

Available

A.E60

Command Option Module

IF Data Communications

Error

A error occurred in communications between the SERVOPACK and
the command option module.

Gr.2

Available

A.E61

Command Option Module

IF Synchronization Error 3

There was a change in timing of synchronization between the SER-
VOPACK and the command option module.

Gr.2

Available

A.E70

Command Option Module

Detection Failure

Detection of the command option module failed.

Gr.1

N/A

A.E71

Safety Option Module

Detection Failure

Detection of the safety option module failed.

Gr.1

N/A

A.E72

Feedback Option Module

Detection Failure

Detection of the Feedback Option Module failed.

Gr.1

N/A

A.E73

Unsupported Command

Option Module

An unsupported command option module was connected.

Gr.1

N/A

A.E74

Unsupported Safety

Option Module

An unsupported safety option module was connected.

Gr.1

N/A

A.E75

Unsupported Feedback

Option Module

An unsupported feedback option module was connected.

Gr.1

N/A

A.E80

Command Option Module

Unmatched Error

The command option module was replaced with a different model.

Gr.1

N/A

A.E81

*2

SERVOPACK: Safety

Module Alarm

A.EA2

DRV Alarm 2

(SERVOPACK WDC error) A SERVOPACK DRV alarm 0 occurs.

Gr.2

Available

A.Eb1

Safety Function Signal

Input Timing Error

The safety function signal input timing is faulty.

Gr.1

N/A

A.Eb

*2

SERVOPACK: Safety

Module Alarms

A.EC

*2

SERVOPACK: Safety

Module Alarms

A.ED1

Command Option Module

IF Command Timeout

Error

Processing of reference from the command option module was not
completed.

Gr.2

Available

A.F10

Main Circuit Cable Open

Phase

With the main circuit power supply ON, voltage was low for more
than 1 second in phase R, S, or T.

Gr.2

Available

A.F30

Dynamic Brake Contactor

Error

An error occurred in the operation of the dynamic brake contactor.

Gr.2

Available

FL-1

*3

System Alarm

Internal program error occurred in the SERVOPACK

N/A

FL-2

*3

N/A

CPF00

Digital Operator

Transmission Error 1

Digital operator (JUSP-OP05A-1-E) fails to communicate with the
SERVOPACK (e.g., CPU error).

N/A

CPF01

Digital Operator

Transmission Error 2

N/A

A.

− −

Not an error

Normal operation status

∗2. These alarms occur in SERVOPACKs with safety modules.

For details, refer to

Σ

-V Series User’s Manual, Safety Module (No.: SIEP C720829 06).

∗3. These alarms are not stored in the alarm history and are displayed only in the panel display.

(cont’d)

Alarm

Number

Alarm Name

Meaning

Servomotor

Stopping

Method

Alarm

Reset

Advertising