Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual

Page 350

Advertising
background image

10.1 List of Parameters

10-21

10

Ap

pend

ix

Pn512

2

Output Signal Inverse Setting

0000 to 0111

0000

After restart

Setup

3.4.2

Pn513

2

Reserved (Do not change.)

0000

Pn515

2

Input Signal Selection 6

0000 to

FFFF

8888

After restart

Setup

Pn517

2

Reserved (Do not change.)

0000

Pn51B

4

Excessive Error Level between Servomo-
tor and Load Positions

0 to

1073741824

1

reference

unit

1000

Immediately

Setup

8.3.6

Pn51E

2

Excessive Position Error Warning Level

10 to 100

1%

100

Immediately

Setup

9.2.1

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Reference

Section

Output Signal Inversion for CN1-25 or -26 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Output Signal Inversion for CN1-27 or -28 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Output Signal Inversion for CN1-29 or -30 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Reserved (Do not change.)

Reserved (Do not change.)

Dynamic Brake Answer signal 1 Input Signal Mapping (/DBANS1)

Reference

Section

0

Detects dynamic brake (DB) contactor errors when the input signal of CN1-40 is ON (closed) while
the DB is applied.

3.9.4

1

Detects DB contactor errors when the input signal of CN1-41 is ON (closed) while the DB is applied.

2

Detects DB contactor errors when the input signal of CN1-42 is ON (closed) while the DB is applied.

3

Detects DB contactor errors when the input signal of CN1-43 is ON (closed) while the DB is applied.

4

Detects DB contactor errors when the input signal of CN1-44 is ON (closed) while the DB is applied.

5

Detects DB contactor errors when the input signal of CN1-45 is ON (closed) while the DB is applied.

6

Detects DB contactor errors when the input signal of CN1-46 is ON (closed) while the DB is applied.

7, 8

Disables DB contactor error detection of DB answer signal 1.

9

Detects DB contactor errors when the input signal of CN1-40 is OFF (open) while the DB is applied.

A

Detects DB contactor errors when the input signal of CN1-41 is OFF (open) while the DB is applied.

B

Detects DB contactor errors when the input signal of CN1-42 is OFF (open) while the DB is applied.

C

Detects DB contactor errors when the input signal of CN1-43 is OFF (open) while the DB is applied.

D

Detects DB contactor errors when the input signal of CN1-44 is OFF (open) while the DB is applied.

E

Detects DB contactor errors when the input signal of CN1-45 is OFF (open) while the DB is applied.

F

Detects DB contactor errors when the input signal of CN1-46 is OFF (open) while the DB is applied.

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising