10.1 List of Parameters

10-11

10

Ap

pend

ix

Pn143

2

Model Following Control Bias
(Forward Direction)

0 to 10000

0.1%

1000

Immediately

Tuning

Pn144

2

Model Following Control Bias
(Reverse Direction)

0 to 10000

0.1%

1000

Immediately

Tuning

Pn145

2

Vibration Suppression 1
Frequency A

10 to 2500

0.1 Hz

500

Immediately

Tuning

Pn146

2

Vibration Suppression 1

Frequency B

10 to 2500

0.1 Hz

700

Immediately

Tuning

Pn147

2

Model Following Control Speed Feedfor-
ward
Compensation

0 to 10000

0.1%

1000

Immediately

Tuning

Pn148

2

2nd Model Following Control Gain

10 to 20000

0.1/s

500

Immediately

Tuning

Pn149

2

2nd Model Following Control Gain Com-

pensation

500 to 2000

0.1%

1000

Immediately

Tuning

Pn14A

2

Vibration Suppression 2
Frequency

10 to 2000

0.1 Hz

800

Immediately

Tuning

Pn14B

2

Vibration Suppression 2 Compensation

10 to 1000

1%

100

Immediately

Tuning

Pn14F

2

Reserved (Do not change.)

0011

Pn160

2

Anti-Resonance Control Related Switch

0000 to 0011

0010

Immediately

Tuning

5.3.1,
5.4.1,
5.5.1,

5.7.1

Pn161

2

Anti-Resonance Frequency

10 to 20000

0.1 Hz

1000

Immediately

Tuning

Pn162

2

Anti-Resonance Gain
Compensation

1 to 1000

1%

100

Immediately

Tuning

Pn163

2

Anti-Resonance Damping Gain

0 to 300

1%

0

Immediately

Tuning

Pn164

2

Anti-Resonance Filter Time Constant 1
Compensation

-1000 to

1000

0.01 ms

0

Immediately

Tuning

Pn165

2

Anti-Resonance Filter Time Constant 2
Compensation

-1000 to

1000

0.01 ms

0

Immediately

Tuning

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Reference

Section

Anti-Resonance Control Selection

0

Does not use anti-resonance control.

1

Uses anti-resonance control.

Anti-Resonance Control Adjustment Selection

0

Does not adjust anti-resonance control automatically using utility function.

1

Adjusts anti-resonance control automatically using utility function.

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising