3 i/o signal connections, 1 i/o signal (cn1) names and functions, 1) input signals – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual

Page 69

Advertising
background image

3.3 I/O Signal Connections

3-23

3

Wi

ring and

C

onne

ctio

n

3.3 I/O Signal Connections

This section describes the names and functions of I/O signals (CN1). Also connection examples by control

method are shown.

3.3.1 I/O Signal (CN1) Names and Functions

The following table shows the names and functions of I/O signals (CN1).

(1) Input Signals

Note 1. The allocation of the input signals (P-OT, N-OT, /SI1, /SI4 to /SI6) can be changed. For details, refer to 3.4.1

Input Signal Allocations.

2. If the Forward run prohibited/ Reverse run prohibited function is used, the SERVOPACK or converter is stopped

by software controls, not by electrical or mechanical means. If the application does not satisfy the safety require-
ments, add an external circuit for safety reasons as required.

• The number of pins on the CN1 connector is different on a large-capacity

Σ-V SER-

VOPACK (50 pins) and a standard

Σ-V SERVOPACK (26 pins). If you are using both

types of SERVOPACK, use the correct connector model numbers when ordering and
the correct signal assignments.

• Regarding the allocation and use of I/O signals, they differ in accordance with the

connected option module. For details, refer to the manual for the command option
module that is connected.

Signal Pin No.

Name

Function

Refer-

ence

Section

P-OT
N-OT

42
43

Forward run
prohibited,
Reverse run
prohibited

With overtravel prevention: Stops servomotor when movable
part travels beyond the allowable range of motion.

4.2.2

/SI1

41

Command option
module input 1

Connects the external input signal used in the command
option module.

/SI4
/SI5
/SI6

44
45
46

Command option
module input 4
Command option
module input 5
Command option
module input 6

Connects the external input signal used in the command
option module.

/SI0

40

General-purpose input
signal

Connects the external input signal used in the command
option module.

+24VIN 47

Control power supply
for sequence signal

Control power supply input for sequence signals.
Allowable voltage fluctuation range: 11 to 25 V
Note: The 24 VDC power supply is not included.

3.5.1

BAT (+)
BAT (-)

21
22

Battery (

+) input signal

Battery (-) input signal

Connecting pin for the absolute encoder backup battery.
Do not connect when the encoder cable with the battery case
is used.

3.7.2
4.5.1

/P-CL
/N-CL
/DBANS

Can be
allocated

Forward external
torque limit
Reverse external
torque limit
Dynamic brake answer
signal

The allocation of an input signal to a pin can be changed in
accordance with the function required.