3 Wiring and Connection

3.1.2 Main Circuit Wire

3-10

For Three-phase, 400 V

∗ Use SERVOPACKs and converters in the specified combinations.

Combination of SERVOPACK and

Converter

*

Terminal Symbols

Screw Size for

Terminals

Tightening

Torque

(N m)

Wire Size AWG

SGDV-750J

SGDV-

COA3ZDA

SERVOPACK

P, N

M8

15.0

Bus bar attached

to the converter

U, V, W

M8

3.0

3

DU, DV, DW

M6

3.0

10

M8

9.0 to 11.0

3

Converter

P, N

M8

3.0

Bus bar attached

to the converter

L1, L2, L3

M8

3.0

3

1, 2

M8

3.0 3

CN101

(24 V, 0 V)

(Connector)

14

B1, B2

M8

3.0

8

M8

9.0 to 11.0

3

SGDV-101J

SGDV-

COA5EDA

SERVOPACK

P, N

M8

15.0

Bus bar attached

to the converter

U, V, W

M8

3.0

1

DU, DV, DW

M6

3.0

10

M8

9.0 to 11.0

1

Converter

P, N

M10

12 to 20

Bus bar attached

to the converter

L1, L2, L3

M10

12 to 20

2

1, 2

M10

12 to 20

2

CN101

(24 V, 0 V)

(Connector)

14

B1, B2

M10

12 to 20

8

M8

9.0 to 11.0

2

SGDV-131J

SGDV-

COA5EDA

SERVOPACK

P, N

M10

12 to 20

Bus bar attached

to the converter

U, V, W

M10

30.0

2/0

DU, DV, DW

M6

3.0

10

M8

9.0 to 11.0

2/0

Converter

P, N

M10

12 to 20

Bus bar attached

to the converter

L1, L2, L3

M10

12 to 20

2/0

1, 2

M10

12 to 20

2/0

CN101

(24 V, 0 V)

(Connector)

14

B1, B2

M10

12 to 20

4

M8

9.0 to 11.0

2/0