4 limiting torque, 1 internal torque limit, Rotation – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual

Page 127

Advertising
background image

4.4 Limiting Torque

4-31

4

Ope

rat

ion

4.4 Limiting Torque

The SERVOPACK provides the following four methods for limiting output torque to protect the machine.

∗ For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).

Note: The maximum torque of the servomotor is used when the set value exceeds the maximum torque.

4.4.1 Internal Torque Limit

This function always limits maximum output torque by setting values of following parameters.

The setting unit is a percentage of the rated torque.

Note: If the settings of Pn402 and Pn403 are too low, the torque may be insufficient for acceleration or deceleration of the

servomotor.

Torque waveform

Limiting Method

Description

Reference Sec-

tion

Internal torque limit

Always limits torque by setting the parameter.

4.4.1

External torque limit

Limits torque by input signal from the host controller.

4.4.2

Torque limit with P_TLIM,
N_TLIM commands

*

Limit torque by using the P_TLIM and N_TLIM commands.

Torque limit with command
option module

Limits torque by inputting a desired torque limit command to the
command option module from the host controller.

Refer to the manual

of the commnad

option module to

be connected.

Pn402

Forward Torque Limit

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Setup

Pn403

Reverse Torque Limit

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Setup

Speed

Position

Torque

Speed

Position

Torque

Speed

Maximum torque

t

Speed

Pn403

Pn402

Limiting torque

t

No Internal Torque Limit

(Maximum torque can be output)

Internal Torque Limit

Rotation

Advertising