Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual

Page 316

Advertising
background image

9.1 Alarm Displays

9-21

9

Trou

blesh

ooting

A.E75:
Unsupported

Feedback Option

Module

A feedback option module fault

occurred.

Replace the feedback option mod-
ule.

A unsupported feedback option

module was connected.

Refer to the catalog of the con-
nected feedback option module or
the manual of the SERVOPACK.

Connect a compatible feedback

option module.

A.E80:
Command Option

Module Unmatched

Error

The command option module was
replaced with a different model.

Execute Fn014 (Resetting configu-
ration error of option module) with

the digital operator or SigmaWin+
and turn the power supply OFF and
then ON again.

A.EA2:
DRV Alarm 2
(SERVOPACK WDC

error)

The timing of synchronization

between the servomotor and
command option module changed
due to change in the communica-

tions cycle of the host controller
connected to the command option
module.

Turn the power supply OFF and

then ON again. If the alarm occurs
again, restart communications
processing from the host controller.

The connection between the
SERVOPACK and the command

option module is faulty.

Check the connection between the
SERVOPACK and the command

option module.

Correctly connect the command
option module.

A command option module fault
occurred.

Replace the command option mod-
ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.Eb1:
Safety Function Signal

Input Timing Error

The lag between activations of

the input signals /HWBB1 and

/HWBB2 for the HWBB function

is ten second or more.

Measure the time lag between the /

HWBB1 and

/HWBB2 signals.

The output signal circuits or devices

for /HWBB1 and

/HWBB2 or the SERVOPACK

input signal circuits may be faulty.

Alternatively, the input signal

cables may be disconnected. Check

if any of these items are faulty or

have been disconnected.

A.ED1:
Command Option

Module IF Command

Timeout Error

Processing of the sensor ON
command from the command
option module is not completed.

Input a servo ON command when
the motor is stopped.

Processing of the sensor ON
command from the command
option module is not completed.

Check that the encoder is connected
correctly and input a sensor ON
command when the motor is
stopped.

A.F10:
Main Circuit Cable

Open Phase
(With the main circuit

power supply ON, volt-

age was low for more

than 1 second in an R, S,

or T phase.)
(Detected when the main

power supply was turned

ON.)

The three-phase power supply

wiring is incorrect.

Check the power supply wiring.

Confirm that the power supply is

correctly wired.

The three-phase power supply is

unbalanced.

Measure the voltage at each phase

of the three-phase power supply.

Balance the power supply by chang-

ing phases.

The connection of the I/O signals

(CN901) between the SERVO-

PACK and converter is faulty.

Check the connection of CN901.

Correctly connect CN901.

A fault occurred in the SERVO-
PACK or converter.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK or con-
verter may be faulty. Replace the
SERVOPACK or converter.

A.F30:
Dynamic Brake

Contactor Error

The contactor is faulty in the
dynamic brake circuit.

Check the contacts to see if they are
welded or not.

The contactor may be faulty.
Replace the contactor.

Incorrect wiring of the dynamic
brake answer signal.

Check the wiring of the dynamic
brake answer signal.

Correctly wire the dynamic brake
answer signal.

A fault occurred in the SERVO-
PACK.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions