2) hard wire base block (hwbb) state, M-ii – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Command Option Interface User Manual

Page 151

Advertising
background image

4.7 Safety Function

4-55

4

Ope

rat

ion

(2) Hard Wire Base Block (HWBB) State

The SERVOPACK will be in the following state if the HWBB function operates. If the /HWBB1 or /HWBB2

signal is OFF, the HWBB function will operate and the SERVOPACK will enter a hard wire baseblock
(HWBB) state.

The HWBB function operates after the servomotor power is turned OFF.

The HWBB function operates while the servomotor power is ON.

/HWBB1
/HWBB2

Reference from
option module

Motor power state

Not applied

(Normal operation)

(Requests motor current shutoff.)

(Normal operation)

(Requests motor current shutoff.)

Applied

Not applied

/HWBB1
/HWBB2

Motor power state

[

Servo ON command is

turned OFF.

]

SERVOPACK
state

ON

OFF

HWBB state

BB state

Operation

SERVOPACK
state

ON

OFF

HWBB state

Operation

Applied

M-II