9.1 Alarm Displays

9-19

9

Trou

blesh

ooting

A.E02:
Command Option

Module IF

Synchronization Error

1

The timing of synchronization
between the servomotor and com-
mand option module changed due
to change in the communications
cycle of the host controller con-

nected to the command option
module.

Turn the power supply OFF and
then ON again. If the alarm occurs

again, restart communications pro-
cessing from the host controller.

The connection between the
SERVOPACK and the command
option module is faulty.

Check the connection between the
SERVOPACK and the command
option module.

Correctly connect the command
option module.

A command option module fault
occurred.

Replace the command option mod-
ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E03:
Command Option

Module IF

Communications Data

Error

An error occurred due to noise in
the communications between the
SERVOPACK and the command
option module.

Take measures against noise.

The connection between the
SERVOPACK and the command
option module is faulty.

Check the connection between the
SERVOPACK and the command
option module.

Correctly connect the command
option module.

A command option module fault
occurred.

Replace the command option mod-
ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E40:
Command Option

Module IF

Communications

Setting Error

A command option module fault
occurred.

Replace the command option mod-
ule.

A.E50:
Command Option

Module IF

Synchronization Error

2

The timing of synchronization
between the servomotor and com-
mand option module changed due
to change in the communications
cycle of the host controller con-
nected to the command option
module.

Turn the power supply OFF and
then ON again. If the alarm occurs
again, restart communications pro-
cessing from the host controller.

A.E51:
Command Option

Module IF

Synchronization

Establishment Error

A command option module fault
occurred.

Replace the command option mod-
ule.

A.E60:
Command Option

Module IF Data

Communications Error

An error occurred due to noise in
the communications between the
SERVOPACK and the command
option module.

Take measures against noise.

The connection between the
SERVOPACK and the command
option module is faulty.

Check the connection between the
SERVOPACK and the command
option module.

Correctly connect the command
option module.

A command option module fault
occurred.

Replace the command option mod-

ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.