6-12

Maintenance

Date en cours : 10 janvier 2008
C:\Documents and Settings\g097447\Bureau\LU 253068043 HFC colour USB - UTAX EN\MaintenanceGb.fm



Gently pull the main charger handle out and push it back in. Repeat this 2 to 3 times. These
movements clean the grid. After cleaning, make sure you restore the main charger unit to its
home position.

Note:

If the main charger unit is not restored to its home position, the corresponding color will be printed over the
whole page.



Remove the grid cleaner from the printer and discard it. The grid cleaner cannot be reused.


Use the same procedure to clean the main charger units for the other toner containers.


Proceed to the next section and clean the advanced beam array lenses.

Cleaning the Advanced Beam Array Lenses

If lines, etc., appear on printed copies, the printouts appear dirty, or faint or blurred printouts are
produced, clean the advanced beam array lenses.
There is 1 lens on the main charger unit of each toner container. The following example explains the
procedure to clean the lens on the main charger unit of the black toner container.