TA Triumph-Adler CLP 4524 User Manual

Page 137

Advertising
background image

Maintenance

6-25

Date en cours : 10 janvier 2008
C:\Documents and Settings\g097447\Bureau\LU 253068043 HFC colour USB - UTAX EN\MaintenanceGb.fm

Op

er

ati

on

Setting yo

ur

machine

Getting started

Director

y

Mainte

nanc

e

Safety

Contents

Installation

Faint or blurred
printing

Clean the main charger units.
Open the left cover. Slowly pull the green wire cleaner knob to each of
the main charger units in and out a few times. For full details, see
Cleaning the Main Charger Unit on p. 6-10.

Clean the advanced beam array lenses.
Open the left cover. Slowly pull the green lens cleaner knob in and out 2
times. For full details, see Cleaning the Advanced Beam Array Lenses on
p. 6-12
.

Make sure the paper type setting is correct the paper being used.
See the Using the Operator Panel section in the Advanced Operation
Guide
.

Conduct color calibration either by switching the printer off then on or
using the printer operator panel. For full details, see the Using the
Operator Panel
section in the Advanced Operation Guide.

Try adjusting the color control settings using the printer driver.

Check the operator panel. If the Toner low (C/M/Y/K) message is
displayed with color description, install a new toner kit for the color. To
replace toner, see Toner Container Replacement on p. 6-3.

Refresh drum.
Perform the following procedures on the operator panel and try cleaning
the drum surface using the printer's built-in cleaning system.



Press [MENU].



Press

or

repeatedly until

>Others

appears.



Press

. Press

or

repeatedly until

e >Service appears.



Press

. Press

or

repeatedly until

>>Drum appears.



Press [ENTER] twice.



The message display shows Please wait. After approx. 3 minutes,
the display returns to Ready.

Printed Results

Corrective Action