Troubleshooting

10-15

10

Error Code:3101

Is the server operating
correctly?

Make sure that the network
environment (server, hub, or other
LAN network) is operating correctly.

Is an authentication method
set for which the server
cannot respond normally?

Check the settings on the server and
client. (For example, make sure the
SMTP/POP authentication enable/
disable settings are the same on the
server and on the client.)

Error Code:3201

Is a non-supported SMTP
authentication method
enabled?

Check the SMTP authentication
settings on the server and client. The
SMTP authentication methods below
can be used on the machine.
CRAM-MD5 / DIGEST-MD5 / PLAIN /
LOGIN

Error Code:4201,
5101, 5102, 5103, 5104,
7101, 7102, 720f

Turn the main power switch off and
then on. If this occurs repeatedly,
write down the error code that
appears in the message display and
contact a service technician. (See the
procedure in

Machine failure. Call

service.

)

Error Code:9181

Have more than 999 original
pages been scanned?

If there are more than 999 original
pages, send the pages in separate
batches.

Error Message

Checkpoints

Corrective Actions

Reference

Page