MegaRAID SAS Software User Guide

Chapter 4: WebBIOS Configuration Utility

|

CacheCade Configuration

Figure 71:

Virtual Drive Properties

2. Select the Enable SSD Caching or Disable SSD Caching radio button in the

Operations frame.

3. Click Go. A confirmation page appears asking you to confirm your selection.

4. Click Yes.

4.6.2.3

Enabling/Disabling SSD

Caching on Multiple Virtual Drives

You can enable and disable SSD caching on multiple virtual drives at one time.

When you enable SSD caching on a virtual drive, that virtual drive becomes associated
with an existing or with a future CacheCade virtual drive. This option is only available
when there is at least one virtual drive in the configuration.

When you disable SSD caching on a virtual drive, any associations that the selected
virtual drive has with a CacheCade virtual drive is removed. This option is only available
when there is at least one virtual drive in the configuration.

Perform the following steps to enable/disable SSD Caching on multiple virtual drives:

1. In the WebBIOS CU main screen, click Controller Properties in the left frame. The

Controller Properties screen appears.

2. Click Next until you reach the last controller properties screen.

3. Click Manage (next to SSD Caching). The Manage SSD Caching screen appears.