Avago Technologies MegaRAID Fast Path Software User Manual

Page 476

Advertising
background image

Page 476

LSI Corporation Confidential

|

July 2011

MegaRAID SAS Software User Guide

Appendix A: Events and Messages

|

Event Messages

0x004f

Fatal

Reconstruction resume of %s failed due to configuration
mismatch

0x0050

Information

Reconstruction started on %s

0x0051

Information

State change on %s from %s to %s

0x0052

Information

Drive Clear aborted on %s

0x0053

Critical

Drive Clear failed on %s (Error %02x)

0x0054

Progress

Drive Clear progress on %s is %s

0x0055

Information

Drive Clear started on %s

0x0056

Information

Drive Clear completed on %s

0x0057

Warning

Error on %s (Error %02x)

0x0058

Information

Format complete on %s

0x0059

Information

Format started on %s

0x005a

Critical

Hot Spare SMART polling failed on %s (Error %02x)

0x005b

Information

Drive inserted: %s

0x005c

Warning

Drive %s is not supported

0x005d

Warning

Patrol Read corrected medium error on %s at %lx

0x005e

Progress

Patrol Read progress on %s is %s

0x005f

Fatal

Patrol Read found an uncorrectable medium error on %s at
%lx

0x0060

Critical

Predictive failure: CDB: %s

0x0061

Fatal

Patrol Read puncturing bad block on %s at %lx

0x0062

Information

Rebuild aborted by user on %s

0x0063

Information

Rebuild complete on %s

0x0064

Information

Rebuild complete on %s

0x0065

Critical

Rebuild failed on %s due to source drive error

0x0066

Critical

Rebuild failed on %s due to target drive error

0x0067

Progress

Rebuild progress on %s is %s

0x0068

Information

Rebuild resumed on %s

0x0069

Information

Rebuild started on %s

0x006a

Information

Rebuild automatically started on %s

0x006b

Critical

Rebuild stopped on %s due to loss of cluster ownership

0x006c

Fatal

Reassign write operation failed on %s at %lx

0x006d

Fatal

Unrecoverable medium error during rebuild on %s at %lx

0x006e

Information

Corrected medium error during recovery on %s at %lx

0x006f

Fatal

Unrecoverable medium error during recovery on %s at %lx

0x0070

Information

Drive removed: %s

0x0071

Warning

Unexpected sense: %s, CDB%s, Sense: %s

0x0072

Information

State change on %s from %s to %s

0x0073

Information

State change by user on %s from %s to %s

Table 150: Event Messages (Continued)

Number

Severity Level

Event Text

Advertising