Avago Technologies MegaRAID Fast Path Software User Manual
Page 476

Page 476
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Appendix A: Events and Messages
|
Event Messages
0x004f
Fatal
Reconstruction resume of %s failed due to configuration
mismatch
0x0050
Information
Reconstruction started on %s
0x0051
Information
State change on %s from %s to %s
0x0052
Information
Drive Clear aborted on %s
0x0053
Critical
Drive Clear failed on %s (Error %02x)
0x0054
Progress
Drive Clear progress on %s is %s
0x0055
Information
Drive Clear started on %s
0x0056
Information
Drive Clear completed on %s
0x0057
Warning
Error on %s (Error %02x)
0x0058
Information
Format complete on %s
0x0059
Information
Format started on %s
0x005a
Critical
Hot Spare SMART polling failed on %s (Error %02x)
0x005b
Information
Drive inserted: %s
0x005c
Warning
Drive %s is not supported
0x005d
Warning
Patrol Read corrected medium error on %s at %lx
0x005e
Progress
Patrol Read progress on %s is %s
0x005f
Fatal
Patrol Read found an uncorrectable medium error on %s at
%lx
0x0060
Critical
Predictive failure: CDB: %s
0x0061
Fatal
Patrol Read puncturing bad block on %s at %lx
0x0062
Information
Rebuild aborted by user on %s
0x0063
Information
Rebuild complete on %s
0x0064
Information
Rebuild complete on %s
0x0065
Critical
Rebuild failed on %s due to source drive error
0x0066
Critical
Rebuild failed on %s due to target drive error
0x0067
Progress
Rebuild progress on %s is %s
0x0068
Information
Rebuild resumed on %s
0x0069
Information
Rebuild started on %s
0x006a
Information
Rebuild automatically started on %s
0x006b
Critical
Rebuild stopped on %s due to loss of cluster ownership
0x006c
Fatal
Reassign write operation failed on %s at %lx
0x006d
Fatal
Unrecoverable medium error during rebuild on %s at %lx
0x006e
Information
Corrected medium error during recovery on %s at %lx
0x006f
Fatal
Unrecoverable medium error during recovery on %s at %lx
0x0070
Information
Drive removed: %s
0x0071
Warning
Unexpected sense: %s, CDB%s, Sense: %s
0x0072
Information
State change on %s from %s to %s
0x0073
Information
State change by user on %s from %s to %s
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e