4 flush controller cache, 5 set controller properties – Avago Technologies MegaRAID Fast Path Software User Manual
Page 232

Page 232
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Controller Property-Related Options
5.8.4
Flush Controller Cache
Use the command in the following table to flush the controller cache on the selected
controllers. This option sends the contents of cache memory to the virtual drives. If the
MegaRAID system must be powered down rapidly, you must flush the contents of the
cache memory to preserve data integrity.
5.8.5
Set Controller Properties
This command sets the properties on the selected controllers. For example, for
{RebuildRate -val}
, you can enter a percentage between 0 percent and 100
percent as the value for the rebuild rate. (The rebuild rate is the percentage of the
compute cycles dedicated to rebuilding failed drives.) At 0 percent, the rebuild is done
only if the system is not doing anything else. At 100 percent, the rebuild has a higher
priority than any other system activity.
NOTE: LSI recommends the default rebuild rate of 30 percent, and the default patrol
read rate of 30 percent.
Use the command in
to display the list of properties you can set for the
controllers.
Table 50: Cache Flush on Selected Controller
Convention
MegaCli –AdpCacheFlush -aN|-a0,1,2|-aALL
Description
Flushes the controller cache on the selected controllers.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e