MegaRAID SAS Software User Guide

Chapter 5: MegaRAID Command Tool

|

Controller Property-Related Options

5.8.4

Flush Controller Cache

Use the command in the following table to flush the controller cache on the selected
controllers. This option sends the contents of cache memory to the virtual drives. If the
MegaRAID system must be powered down rapidly, you must flush the contents of the
cache memory to preserve data integrity.

5.8.5

Set Controller Properties

This command sets the properties on the selected controllers. For example, for
{RebuildRate -val}

, you can enter a percentage between 0 percent and 100

percent as the value for the rebuild rate. (The rebuild rate is the percentage of the
compute cycles dedicated to rebuilding failed drives.) At 0 percent, the rebuild is done
only if the system is not doing anything else. At 100 percent, the rebuild has a higher
priority than any other system activity.

NOTE: LSI recommends the default rebuild rate of 30 percent, and the default patrol
read rate of 30 percent.

Use the command in

Table 51

to display the list of properties you can set for the

controllers.

Table 50: Cache Flush on Selected Controller

Convention

MegaCli –AdpCacheFlush -aN|-a0,1,2|-aALL

Description

Flushes the controller cache on the selected controllers.