Avago Technologies MegaRAID Fast Path Software User Manual

Page 77

Advertising
background image

LSI Corporation Confidential

|

July 2011

Page 77

MegaRAID SAS Software User Guide

Chapter 4: WebBIOS Configuration Utility

|

Creating a Storage Configuration

Update Size: Click Update Size to update the Select size field value for the

selected RAID levels

8. Click Accept to accept the changes to the virtual drive definition.

If you need to undo the changes, click Reclaim.

9. Click Next after you finish defining the virtual drives.

The Configuration Preview dialog appears, as shown in

Figure 37

.

Figure 37:

RAID 1 Configuration Preview Dialog

10. Check the information in the Configuration Preview dialog.

11. If the virtual drive configuration is acceptable, click Accept to save the

configuration. Otherwise, click Back to return to the previous dialogs and change
the configuration.

12. If you accept the configuration, click Yes at the prompt to save the configuration.

The WebBIOS main menu appears.

4.5.2.3

Using Manual

Configuration: RAID 5

RAID 5 uses drive striping at the block level and parity. In RAID 5, the parity information
is written to all drives. It is best suited for networks that perform a lot of small
input/output (I/O) transactions simultaneously. RAID 5 provides data redundancy, high
read rates, and good performance in most environments. It also provides redundancy
with lowest loss of capacity.

RAID 5 provides high data throughput. RAID 5 is useful for transaction processing
applications because each drive can read and write independently. If a drive fails, the
RAID controller uses the parity drive to re-create all missing information. You can use
RAID 5 for office automation and online customer service that require fault tolerance.

Advertising