Chapter 5: MegaRAID Command Tool

|

Configuration-Related Options

Table 73: Create a Drive Group from All of the Unconfigured Drives

Convention

MegaCli –CfgLDAdd -RX[E0:S0,E1:S1,...] [WT | WB] [NORA | RA | ADRA] [Direct |
Cached] [CachedBadBBU|NoCachedBadBBU] [-szXXX [-szYYY ...]] [-strpszM]
[-Hsp[E0:S0,...]] [-AfterLdX] | | -Force [FDE|CtrlBased]

Description

Creates one RAID drive group out of all of the Unconfigured Good drives, and a hot spare, if desired. This is for RAID
levels 0, 1, 5, or 6. All free drives are used to create a new drive group and, if desired, one hot spare drive.

-Rx[E0:S0,...]

: Specifies the RAID level and the drive enclosure/slot numbers used to construct a drive group.

-WT

(Write Through), WB (Write Back): Selects the write policy.

-NORA

(No Read Ahead), RA (Read Ahead), ADRA (Adaptive Read Ahead): Selects the read policy.

-Direct

, -Cached: Selects the cache policy.

-CachedBadBBU|NoCachedBadBBU

: Specifies whether to use write cache when the BBU is bad.

Hsp

: Specifies the drive with which to make the hot spare.

-Force

: Specifies that drive coercion is used to make the capacity of the drives compatible. Drive coercion is a tool

for forcing drives of varying capacities to the same capacity so they can be used in a drive group.

NOTE: Previously, -szXXX expressed capacity in MB, but now you can enter the capacity in your choice of units. For
example, to create a virtual drive of 10 GB, enter the size as sz10GB. If you do not enter a unit, MB is the default unit.

Advertising