Chapter 11: Using MegaRAID Advanced Software
|
LSI SafeStore Encryption Services
11.6.12.1 Foreign Configurations
in Cable Pull and Drive Removal
Scenarios
If one or more drives are removed from a configuration, by a cable pull or drive
removal, for example, the configuration on those drives is considered a foreign
configuration by the RAID controller.
The following scenarios can occur with cable pulls or drive removals. Use the Foreign
Configuration Preview dialog to import or clear the foreign configuration in each case.
NOTE: If you want to import the foreign configuration in any of the following scenarios,
you must have all of the drives in the enclosure before you perform the import
operation.
Scenario #1: If all of the drives in a configuration are removed and re-inserted, the
controller considers the drives to have foreign configurations.
Import or clear the foreign configuration. If you select Import, automatic rebuilds will
occur in redundant virtual drives.
NOTE: Start a consistency check immediately after the rebuild is complete to ensure
data integrity for the virtual drives. See
Section 10.2, Running a Consistency Check
for
more information about checking data consistency.
Scenario #2: If some of the drives in a configuration are removed and re-inserted,
the controller considers the drives to have foreign configurations.
Import or clear the foreign configuration. If you select Import, automatic rebuilds will
occur in redundant virtual drives.
NOTE: Start a consistency check immediately after the rebuild is complete to ensure
data integrity for the virtual drives. See
Section 10.2, Running a Consistency Check
for
more information about checking data consistency.
Scenario #3: If all of the drives in a virtual drive are removed, but at different times,
and re-inserted, the controller considers the drives to have foreign configurations.
Import or clear the foreign configuration. If you select Import, all drives that were
pulled before the virtual drive became offline will be imported and will be
automatically rebuilt. Automatic rebuilds will occur in redundant virtual drives.
Scenario #4: If the drives in a non-redundant virtual drive are removed, the
controller considers the drives to have foreign configurations.
Import or clear the foreign configuration. No rebuilds will occur after the import
operation because there is no redundant data to rebuild the drives.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e