LSI Corporation Confidential

|

July 2011

MegaRAID SAS Software User Guide

Chapter 9: Monitoring Controllers and Its Attached Devices

|

Battery Learn Cycle

Figure 259: Battery Backup Unit Properties for TMM-C Battery

9.20

Battery Learn Cycle

Learn cycle is a battery calibration operation that is performed by the controller
periodically to determine the condition of the battery. You can start battery learn cycles
manually or automatically. To choose automatic battery learn cycles, enable automatic
learn cycles. To choose manual battery learn cycles, disable automatic learn cycles.

If you enable automatic learn cycles, you can delay the start of the learn cycles for up to
168 hours (7 days). If you disable automatic learn cycles, you can start the learn cycles
manually, and you can choose to receive a reminder to start a manual learn cycle.

9.20.1

Setting Learn Cycle Properties

To set the learn cycle properties, perform the following steps:

1. Click the Physical tab to open the Physical view.

2. Select the BBU icon in the left panel.

3. Select Go To->BBU->Set Learn Cycle Properties. The Set Learn Cycle Properties

window appears, as shown in the following figure.