Events and messages, A.1 error levels, A.2 event messages – Avago Technologies MegaRAID Fast Path Software User Manual

Page 473: Appendix a, Appendix a, events and messages, Appendix a: events and messages

Advertising
background image

LSI Corporation Confidential

|

July 2011

Page 473

MegaRAID SAS Software User Guide

Appendix A: Events and Messages

|

Error Levels

Appendix A

MegaRAID Storage Manager software monitors the activity and performance of all
controllers in the workstation and the devices attached to them. When an event occurs,
such as the start of an initialization, an event message appears in the log at the bottom
of the MegaRAID Storage Manager window. The messages are also logged in the
Windows Application log (Event Viewer).

A.1

Error Levels

Each message that appears in the event log has a Severity level that indicates the
severity of the event, as shown in

Table 149

.

A.2

Event Messages

Table 150

lists all of the MegaRAID Storage Manager event messages. The event

message descriptions include placeholders for specific values that are determined
when the event is generated. For example, in message No. 1 in the Event Messages
table, “%s” is replaced by the firmware version, which is read from the firmware when
the event is generated.

Events and Messages

This appendix lists the MegaRAID Storage Manager events that can appear in the

event log.

Table 149: Event Error Levels

Severity Level

Meaning

Information

Informational message. No user action is necessary.

Warning

Some component might be close to a failure point.

Critical

A component has failed, but the system has not lost data.

Fatal

A component has failed, and data loss has occurred or will occur.

Table 150: Event Messages

Number

Severity Level

Event Text

0x0000

Information

MegaRAID firmware initialization started (PCI ID
%04x/%04x/%04x/%04x)

0x0001

Information

MegaRAID firmware version %s

0x0002

Fatal

Unable to recover cache data from TBBU

0x0003

Information

Cache data recovered from TBBU successfully

0x0004

Information

Configuration cleared

0x0005

Warning

Cluster down; communication with peer lost

0x0006

Information

Virtual drive %s ownership changed from %02x to %02x

0x0007

Information

Alarm disabled by user

Advertising