Events and messages, A.1 error levels, A.2 event messages – Avago Technologies MegaRAID Fast Path Software User Manual
Page 473: Appendix a, Appendix a, events and messages, Appendix a: events and messages

LSI Corporation Confidential
|
July 2011
Page 473
MegaRAID SAS Software User Guide
Appendix A: Events and Messages
|
Error Levels
Appendix A
MegaRAID Storage Manager software monitors the activity and performance of all
controllers in the workstation and the devices attached to them. When an event occurs,
such as the start of an initialization, an event message appears in the log at the bottom
of the MegaRAID Storage Manager window. The messages are also logged in the
Windows Application log (Event Viewer).
A.1
Error Levels
Each message that appears in the event log has a Severity level that indicates the
severity of the event, as shown in
.
A.2
Event Messages
lists all of the MegaRAID Storage Manager event messages. The event
message descriptions include placeholders for specific values that are determined
when the event is generated. For example, in message No. 1 in the Event Messages
table, “%s” is replaced by the firmware version, which is read from the firmware when
the event is generated.
Events and Messages
This appendix lists the MegaRAID Storage Manager events that can appear in the
event log.
Table 149: Event Error Levels
Severity Level
Meaning
Information
Informational message. No user action is necessary.
Warning
Some component might be close to a failure point.
Critical
A component has failed, but the system has not lost data.
Fatal
A component has failed, and data loss has occurred or will occur.
Table 150: Event Messages
Number
Severity Level
Event Text
0x0000
Information
MegaRAID firmware initialization started (PCI ID
%04x/%04x/%04x/%04x)
0x0001
Information
MegaRAID firmware version %s
0x0002
Fatal
Unable to recover cache data from TBBU
0x0003
Information
Cache data recovered from TBBU successfully
0x0004
Information
Configuration cleared
0x0005
Warning
Cluster down; communication with peer lost
0x0006
Information
Virtual drive %s ownership changed from %02x to %02x
0x0007
Information
Alarm disabled by user
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e