Event Messages
0x0123
Information
Redundant enclosure EMM %s removed for EMM %s
0x0124
Warning
Patrol Read can't be started, as PDs are either not ONLINE, or
are in a VD with an active process, or are in an excluded VD
0x0125
Information
Copyback aborted by user on PD %s and src is PD %s
0x0126
Critical
Copyback aborted on hot spare %s from %s, as hot spare
needed for rebuild
0x0127
Warning
Copyback aborted on PD %s from PD %s, as rebuild required
in the array
0x0128
Fatal
Controller cache discarded for missing or offline VD %s
When a VD with cached data goes offline or missing during
runtime, the cache for the VD is discarded. Because the VD is
offline, the cache cannot be saved.
0x0129
Information
Copyback cannot be started as PD %s is too small for src PD
%s
0x012a
Information
Copyback cannot be started on PD %s from PD %s, as
SAS/SATA is not supported in an array
0x012b
Information
Microcode update started on PD %s
0x012c
Information
Microcode update completed on PD %s
0x012d
Warning
Microcode update timeout on PD %s
0x012e
Warning
Microcode update failed on PD %s
0x012f
Information
Controller properties changed
0x0130
Information
Patrol Read properties changed
0x0131
Information
CC Schedule properties changed
0x0132
Information
Battery properties changed
0x0133
Warning
Periodic Battery Relearn is pending. Please initiate manual
learn cycle as Automatic learn is not enabled
0x0134
Information
Drive security key created
0x0135
Information
Drive security key backed up
0x0136
Information
Drive security key from escrow, verified
0x0137
Information
Drive security key changed
0x0138
Warning
Drive security key, re-key operation failed
0x0139
Warning
Drive security key is invalid
0x013a
Information
Drive security key destroyed
0x013b
Warning
Drive security key from escrow is invalid
0x013c
Information
VD %s is now secured
0x013d
Warning
VD %s is partially secured
0x013e
Information
PD %s security activated
0x013f
Information
PD %s security disabled
0x0140
Information
PD %s is reprovisioned
0x0141
Information
PD %s security key changed
0x0142
Fatal
Security subsystem problems detected for PD %s
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e