MVI46-DFNT ♦ SLC Platform

User Manual

EtherNet/IP Client/Server Communication Module

Page 154 of 177

ProSoft Technology, Inc.

October 12, 2010

Set the R

EAD

/W

RITE

parameter to R

EAD

.

The module supports a T

ARGET

D

EVICE

parameter value of 500CPU

or PLC5.

In order to complete the configuration of

the MSG instruction, select the S

ETUP

S

CREEN

area of the MSG object. This

displays the following dialog box.

The T

ARGET

D

EVICE

D

ATA

T

ABLE

A

DDRESS

must be set to a valid file element

(such as, N11:0) for SLC and PLC5 messages. The M

ULTI

H

OP

option must be

set to Y

ES

.

Fill in the M

ULTI

H

OP

tab portion of the dialog box as shown in the following

illustration.

Set the IP address value to the module’s Ethernet IP address. You must press

the "Insert" key to add the second line for ControlLogix Backplane and set the

slot number to zero.