SANRAD V-Switch CLI User Manual

Health Monitoring

You can monitor the health of the V-Switch hardware for fan malfunctions that
could lead to overheating as well as power supply malfunctions both of which
can nullify high availability and lead to V-Switch failover.

system hardware show

This command shows all hardware interface connection statistics.

system hardware show

Table 12-1: System

Hardware

Max No. of Power Supplies:

2

PS Status:

1 working

Max No. of Fans:

3

Fan Status:

3 working

CPU Temperature (C):

59

CPU Temperature Threshold (C):

Warning 90;
Faulty 100

CPU Temperature Status:

OK

On-board Temperature (C):

33

On-board Temperature Threshold (C):

Warning 60;
Faulty 70

On-board Temperature Status

OK

You can change the default temperature scale to Fahrenheit using the CLI
command device set –temperature_units f.