Powering up – SANRAD I3.1.1205 User Manual

Page 52

Advertising
background image

3-12

SANRAD V-Switch CLI User Manual

Powering Up

You can power up the V-Switch 3000 once you have connected and powered up
the storage devices. The V-Switch 3000 contains a storage auto-discovery
function. At power- up the V-Switch 3000 automatically scans for and registers
all attached and powered up network storage devices. Therefore, power up all
storage devices before powering up the V-Switch 3000. Storage devices added
after V-Switch 3000 power- up will be registered in the next V-Switch 3000
storage network scan.

The V-Switch 3000 contains two removable auto-switch 100V/230V AC
redundant power supplies.

Redundant

Power Supplies

102

4

2

Figure 3-13. V-Switch 3000 Power Supplies

Reconfirm that all storage devices are powered up and connected to the V-
Switch. Plug the power cables into the V-Switch 3000 power supplies and then
into the power source. Push the power switch to the ON position. The V-
Switch 3000 powers up.

ƒ

The Power indicator LED on the front right of the V-Switch 3000 turns
green.

ƒ

Each network port 1 Gb indicator LED turns green only if connected to
the network and operating at 1 Gb.

ƒ

Each storage port indicator LED on the front right of the V-Switch 3000
is green if connected to storage.

ƒ

The fans start operating.

ƒ

The LCD panel displays “V-Switch 3000 SANRAD Corp.”

You are now able to initialize the V-Switch 3000.