4 sanrad v-switch cli user manual – SANRAD I3.1.1205 User Manual

Page 84

Advertising
background image

5-4

SANRAD V-Switch CLI User Manual

RAID controller are simultaneously exposed through all ports connected
to both V-Switches for the V-Switches to provide high availability during a
V-Switch failover.

In Figure 5-2, V-Switch 1 has gone off-line. V-Switch 2 activates V-Switch 1’s IP
address and takes over exposure of Volume 1 to Host 1, represented by the
orange dashed line.

Host 1 continues to access Volume 1 through the same IP address as it did
before its V-Switch went off-line. Host 1 has no way of knowing that its regular
V-Switch is off-line. Host 1’s storage performance is not impacted by the off-
line V-Switch.

10

2

6

8

Cloud

IP SAN

IP1-inactive
IP2-inactive

IP2-active
IP1-active

Tower box

Host 2

iSCSI

initiator

Vol 2

Vol 1

Tower box

Host 1

iSCSI

initiator

V Switch 1

V Switch 2

Disk 1

Disk 2

Disk 4

Disk 3

iSCSI Target 2

wwui2

iSCSI Target 1

wwui1

Vol 2

LU0

Vol 1

LU0

IP1,Target 1

IP2,Target 2

JBOD

Figure 5-2. Re-routing Storage Access with Off-line V-Switch

Advertising