6 operating characteristics, 1 four-quadrant operation, Introduction – American Magnetics 4Q1010PS-430 Integrated Power Supply System User Manual

Page 27

Advertising
background image

Rev. 5

9

Introduction

Operating Characteristics

1.6 Operating Characteristics

The Model 430 Programmer has

been designed to perform with var-

ious power supplies to allow the

user the greatest degree of system

flexibility. The power supply and

Programmer combination are cate-

gorized by one of three forms: sin-

gle-quadrant, dual-quadrant, and

four-quadrant. For sake of clarity,

the term quadrant is defined as

one of four areas of a cartesian

coordinate system where the

abscissa is current and the ordi-

nate is voltage. Refer to Figure 1-3.

1.6.1

Four-Quadrant Operation

The four-quadrant magnet power supply system illustrated in Figure 1-4

offers the most control of all the modes of operation. Efficiency is increased

and reversible magnetic field profiles are attainable without

discontinuities in the current. All of the voltage and current control is

performed electronically so that system reliability is improved.

Disadvantages of the four-quadrant system include somewhat increased

cost of the power supply over single or dual-quadrant power supplies, and

added complexity in protecting the power supply in the event of AC power

loss or magnet quenching. Nonetheless, modern four-quadrant power

supplies which include integral output protection against AC power loss

and magnet quenching are available at reasonable prices.

20

-20

200

-200

V

I

Positive Current

Flow Direction

Positive Voltage

Polarity

Positive Current

Flow Direction

Negative Voltage

Polarity

Negative Current

Flow Direction

Positive Voltage

Polarity

Negative Current

Flow Direction

Negative Voltage

Polarity

1

2

4

3

Figure 1-3.

The Four Regions, or

Quadrants, of System Operation.

Magnet

Coil(s)

Persistent

Switch

(optional)

Misc. Line Losses

Model 420

Shunt

V

Four-Quadrant

Power Supply

Current

Figure 1-4.

Four-Quadrant System with Resistive Shunt

430