Table 3-3. v-v mode input range picklist values, 2 load submenu, 1 stability setting – American Magnetics 4Q1010PS-430 Integrated Power Supply System User Manual

Page 66: Table 3-3, V-v mode input range picklist values, Operation

Advertising
background image

48

Rev. 5

Operation

Setup Submenu : Load

3.10.1.1.1.4 Max Output Current

The maximum output current is specified in amperes (A) and

reflects the maximum output current capacity of a connected power

supply. The valid range is 0.001 to +2000.000 A

1

, and can be set by

using either the numeric keypad per section 3.3 on page 25 or the

fine adjust knob (section 3.4 on page 26).

3.10.1.1.1.5 V-V Mode Input Range

The voltage-to-voltage mode input range defines the remote

programming voltage input range required by the connected power

supply. The remote programming voltage is the output signal

provided by the Model 430 Programmer as an input to the

connected power supply.

This submenu item provides a picklist of six preset selections and

does not allow numeric entry of a range. The picklist values are

shown in Table 3-3 below.

3.10.2 Load

Submenu

When the Load submenu is selected, several parameters associated with

the superconducting magnet load can be viewed and/or changed.

3.10.2.1

Stability Setting

The stability setting is specified in percent and controls the

transient response and stability of the system. The value can be set

Table 3-3.

V-V Mode Input Range Picklist Values

+0.000 to -5.000

+0.000 to +8.000

+0.000 to +5.000

-5.000 to +5.000

+0.000 to +10.000

-10.000 to +10.000

+0.00 A — Max Output Current (A)

+0.00 Vs

+100.000

+0.00 A — V-V Mode Input Range (V)

+0.00 Vs

-10.000 to +10.000

+0.00 A — Stability Setting (%)
+0.50 Vs

0.0

Advertising