GE Industrial Solutions AF-300E$ User Manual

Page 64

Advertising
background image

LCD
GRAPHIC

FACTORY

FUNCTION

DISPLAY

SETTING

DESCRIPTION

SETTING

6-7

* 14

FREQ GAIN

FREQUENCY GAIN

100.0

Frequency gain is a multiplier on the
frequency set point when an analog refer-
ence is selected (100% equals unity gain).
Adjustable from 0 to 200%.

NOTE: Frequency gain is operative only when

frequency setting method is analog
(Function Code 00 = 1 or 2).

* 15

DRV TORQUE

DRIVING TORQUE

999

This limit puts a hard clamp on the amount
of torque which the drive will provide
in the driving direction (i.e. delivering
power). It is set as a percentage of rated
torque and is adjustable from 20 to 180%.
Setting this Function Code to 999 will remove
the limit. This Function Code can be used to
avoid the breakdown torque region of the
motor (see related Function Code 86 concerning
motor capacity.)

CAUTION: If this Function Code is set too low when compared to the actual load
requirement, the motor may not accelerate.

200%

100%

Output

Frequency

(Gain 200% Example)

Set Signal 100%

(Gain 70% Example)

70%

100%

Output

Frequency

Advertising