Pattern operation method #1: keypad panel – GE Industrial Solutions AF-300E$ User Manual

Page 86

Advertising
background image

LCD
GRAPHIC

FACTORY

FUNCTION

DISPLAY

SETTING

DESCRIPTION

SETTING

6-29

Pattern Operation Method #1: Keypad Panel

The key functions are changed as follows:

RUN key: Start operation

STOP key: Temporary stop of drive
operation (pause)

RESET key: Resets pattern to original
starting point.

The next RUN input will start operation from
pattern stage 1.

NOTE: The RESET key only functions when the drive is stopped or paused.

Stage 1

Stage 2

Stage 3

Stage 4

Stage 5

Stage 6

Stage 7

t

Output

Frequency

Output
Frequency

Stage 1

Stage 2

During this span
time is not
counted

Remaining
operation time
for Time 1

STOP

RUN

RUN

Output

Frequency

Stage 1

Stage 2

Stage 1

Stage 3

Stage 2

RUN

STOP RESET RUN

Advertising