GE Industrial Solutions AF-300E$ User Manual

Page 73

Advertising
background image

LCD
GRAPHIC

FACTORY

FUNCTION

DISPLAY

SETTING

DESCRIPTION

SETTING

6-16

MOTOR #2

NOTE: Motor #2 is a second motor NOT multi-motor.

39

BASE Hz-2

BASE FREQUENCY #2

60

Base frequency for motor #2 is adjustable
from 30 Hz to 400 Hz in 1 Hz steps. Motor
#2 Function Codes become active when Function
Code 32 equals - - 1 and X5 – CM contacts are
closed.
(30 Hz to 120 Hz, 40 Hp & above, var. torque loads.)

WARNING: Review motor capabilities for operation above base frequency.

40

RATED V-2

RATED VOLTAGE #2

230

Maximum output voltage for motor #2 is

(460)

adjustable from 80 to 240 V (230 V Drives)
or 320 to 480 V (460 V Drives). Motor #2
Function Codes become active when Function
Code 32 equals - - - 1 and X5 – CM contacts
are closed.

NOTE: When set at zero (0), the maximum

output voltage will follow the input
AC line voltage. (30 Hp & lower only)

* 41

TRQ BOOST2

TORQUE BOOST #2

2.0

Torque boost for motor #2 can be set to
optimize the V/Hz characteristics of the
drive according to the type of load the
motor will see. Motor #2 Function Codes
become active when Function Code 32 equals
- - - 1 and X5 – CM contacts are closed.

0.1 - 0.9:

Variable torque loads

1.0 - 1.9:

Proportional torque loads

2.0 - 20:

Constant torque loads

* 42

43-51

FUNCTION CODE BLOCK DISPLAY

0

This setting determines whether or not
Function Code 43 through 51 will be
displayed and available for adjustment.

0:

Function Code 43 through 51 NOT displayed.

1:

Function Code 43 through 51 displayed.