GE Industrial Solutions AF-300E$ User Manual

Page 78

Advertising
background image

LCD
GRAPHIC

FACTORY

FUNCTION

DISPLAY

SETTING

DESCRIPTION

SETTING

6-21

* 50

FDT HYSTR

FREQUENCY DETECTION HYSTERESIS

1.0

The setting is the offset that FDT will
have from the FDT level. Adjustable from
0.0 to 30 Hz.

* 51

OL WARNING

OVERLOAD EARLY WARNING

RATED

This open collector output is active when

CURRENT

the output current exceeds the OL setting.
This output can be used in conjunction with
a relay unit to allow connection to system
control circuitry. Adjustable from approx-
imately 20 to 135% of drive rated current.
NOTE: This is a timed function similar to
Function Code 08 and 09 (ELCTRN OL).

* 52

53-59

FUNCTION CODE BLOCK DISPLAY

0

This setting determines whether or not
Function Codes 53 through 59 will be displayed
and available for adjustment.

0:

Function Codes 53 through 59 NOT displayed.

1:

Function Codes 53 through 59 displayed.

Output

Frequency

FDT

Signal

FDT Hyster

FDT Level

Hz

0

t